System information
Program 51 : CygniLink Service
51-09 : CygniLink TCP Port Settings
UX5000 Software Program Manual Programming ◆ 763
51-09 : CygniLink TCP Port Settings
Description
Use Program 51-09 : CygniLink TCP Port Settings to set the various communication ports used
with CygniLink. The port numbers should not be changed while CygniLink is running. Once
changed, the UX5000 must be reset.
Input Data
Level:
Feature Availability
IN • Available.
Item No. Item Input Data Default
01 Primary Port
Define the port the Primary UX5000 uses to
communicate with the Secondary UX5000.
0-65535 58000
02 Communication Port
Define the port used to communicate between
other networked UX5000s.
0-65535 58001
03 Secondary Port
This setting defines the port used by the Sec-
ondary UX5000 to communicates to the Pri-
mary UX5000. If ‘0’ is entered, the port is
selected dynamically.
0-65535 0
04 Primary Search Port
When Fail Over occurs, each UX5000 com-
municates with the other UX5000s using the
port number specified in this entry. If ‘0’ is
entered, the port is selected dynamically.
If an entry other than ‘0’ is made, up to 50
ports (depending in the number of networked
UX5000s) are continuously used from the
specified port number. (Ex: If 5000 is entered,
5001-5049 will be used.)
0-65535 0
05 Primary Detection Port
Enter the port number to search for the Top
Priority Primary UX5000. If ‘0’ is entered, the
port is selected dynamically.
0-65535 0
06 Database Replication Secondary System
Listening Port
Define the listening port used so that the Sec-
ondary UX5000 can replicate the Primary
UX5000 database.
0-65535 58002