System information
Program 51 : CygniLink Service
51-07 : CygniLink Forced Change of Primary System Settings
UX5000 Software Program Manual Programming ◆ 759
51-07 : CygniLink Forced Change of Primary System Settings
Description
Use Program 51-07 : CygniLink Forced Change of Primary System Settings to enable the abil-
ity to manually reset the CygniLink’s Primary UX5000.
Input Data
Conditions
None
Feature Cross Reference
● Networking - CygniLink
Level:
Feature Availability
IN • Available.
Item No. Item Input Data Default
01 Allow Forced Change of Primary System
When Fail Over occurs, you can manually
change the Primary UX5000 using Program
51-08, if this option is enabled.
Program 51-06-01 must be set to “0”.
0 = Disabled
1 = Enabled
0
02 Blade Reset Timing Option
When the Forced Change of Primary Settings is
performed, the blades in the secondary UX5000s
are reset. This option determines if the second-
ary UX5000 blades are reset only when all
blades are idle (0) or at any time (1).
0 = Disabled
1 = Enabled
0