System information
Program 51 : CygniLink Service
51-04 : IP Address for Top Priority Primary System
UX5000 Software Program Manual Programming ◆ 753
51-04 : IP Address for Top Priority Primary System
Description
Use Program 51-04 : IP Address for Top Priority Primary System to define the IP address for
the highest priority Primary UX5000. At the UX5000 start up, if the IP address of the UX5000
matches this entry, the UX5000 is considered the Primary UX5000.
If a Primary UX5000 is already established when the UX5000 with this IP address is powered up,
the newly powered up UX5000 will start as a secondary UX5000 - the Primary/Secondary link will
not be restructured until a Fail Over condition occurs.
Input Data
Conditions
None
Feature Cross Reference
● Networking - CygniLink
Level:
Feature Availability
IN • Available.
Item No. Item Input Data Default
01 Internet Protocol Address
for Top Priority Primary
System
Enter the IP address of the Pri-
mary UX5000. This setting is
needed to use the Primary Sys-
tem Automatic Integration
Feature (Program 51-06-01). If
the secondary flag is set in Pro-
gram 51-01-03 secondary
UX5000s will connect with
this IP address.
0.0.0.0 ~ 126.255.255.254
128.0.0.1 ~ 191.255255.254
192.0.0.1 ~ 223.255.255.254
0.0.0.0