System information

Program 51 : CygniLink Service
51-01 : CygniLink System Settings
UX5000 Software Program Manual Programming 747
Program 51 : CygniLink Service
51-01 : CygniLink System Settings
Description
Use Program 51-01 : CygniLink System Settings to dene the CygniLink settings. Each UX5000
within the network must be dened.
Input Data
Conditions
If the CygniLink system ID is changed in item 1, the UX5000 must be reset.
This program cannot be changed when the CygniLink feature is established.
Level:
Feature Availability
IN Available.
Item No. Item Input Data Default
Related
Programs
01 CygniLink System ID
This is the ID number that identies each UX5000 within
the CygniLink network. Each UX5000 must be a unique
number in the network.
When this option is set to 0, CygniLink is disabled.
The UX5000 must be reset when changing this option.
0-50
(0 = Disabled)
0
02 Primary Candidate Order
When the Primary UX5000 is turned off or disconnected
from the network, this value is used to select the new
Primary UX5000 with the Fail Over feature. The smaller
the number, the higher the priority for the UX5000.
When the value for two UX5000s is the same, lower
CygniLink System ID (51-01-01) is selected as the Pri-
mary UX5000.
1-50 30 51-01-01
03 Secondary System
The link between UX5000s is established based on this
setting.
When enabled, the UX5000 will connect with the top pri-
ority Primary UX5000 (address set in Program 51-04-01).
If the UX5000 is not found within the dened time (Pro-
gram 51-05-02), the Fail Over feature of the UX5000 will
search for the Primary UX5000 (as if this option were set
to ‘0’).
The link between UX5000s is dynamically established
based on the node list set in Program 51-03-01. The Pri-
mary UX5000 will be selected in the order in which the
UX5000s wake up.
0=Disable
1=Enable
0 51-03-01
51-04-01
51-05-02