System information
Program 47 : IntraMail
47-01 : IntraMail System Options
UX5000 Software Program Manual Programming ◆ 695
Conditions
None
Feature Cross Reference
● Voice Mail
Terminal Programming Instructions
To enter data for Program 47-01 (IntraMail Basic Options):
1. Enter the programming mode.
2. 47 01
3. Enter the number of the item you want to program.
4. Enter data for the item you selected + HOLD.
5. Enter data for the next item in the program.
OR
Press MIC once to enter a new item number.
OR
Press MIC until you’ve exited that series’s programming section.
17 Start of IntraMail Port
Use this option to set the IntraMail starting port number.
• This must be an unassigned port.
• To avoid conflicts, you should use the last 16 ports for
IntraMail. The assignment in this option is the first (lowest
numbered) of those last 16 ports.
- For example, in a 64-port UX5000 consider starting at
port 49.
• Note that UX5000 licensing determines the number of
available ports.
Any valid and licensed
extension number available
in the UX5000
(0 = Disabled)
0
47-01-01
DSPDB VM Type 0:Intra
back
↑ ↓ select
47-01-nn