Program 24 : Hold/Transfer Setup
24-02 : System Options for Transfer
452 ◆ Programming UX5000 Software Program Manual
Conditions
None
Feature Cross Reference
● Call Forward
● Tandem Trunking
● Transfer
09 ISDN Transfer Resend Timer
Determine how long the UX5000 should resend a Facility
Message to the currently active PRI trunk when the 2
B-Channel Transfer feature is used. The UX5000 will
resend the Facility timer based on this timer. If there is no
response after the 3rd resend, the UX5000 considers the
transfer as failed and stops resending.
1-30 seconds 10 10-03-16
(PRI)
10 Trunk-to-Trunk Transfer Disconnect Timer
Determine how long a conversation will continue once
the timer in Program 24-02-07 expires. If this option is
set to "0", the conversation will be disconnected immedi-
ately. This program has no affect if Program 24-02-07 is
set to "0". One of the trunks used must be an analog trunk
(or leased line).
0 - 64800 seconds 0 14-01-25
20-28-01
20-28-02
20-28-03
24-02-07
11 No Answer Timer for Step Transfer
Define the length of time the UX5000 will wait before
Step Transferring a no-answer call to the next destination.
0 - 64800 seconds 10 14-01-26
24-04-01
12 No Answer Timer for Automatic Trunk-to-Trunk
Transfer
Define the length of time the UX5000 will wait before
Automatic Trunk-to-Trunk Transfer occurs for a
no-answer call.
0 - 64800 seconds 0 14-01-26
24-04-01