System information
Program 21 : Outgoing Call Setup
21-01 : System Options for Outgoing Calls
360 ◆ Programming UX5000 Software Program Manual
07 Toll Restriction Override Time
After dialing the Toll Restriction Override
codes, the UX5000 removes Toll Restriction
from the extension for this interval.
0-64800 Seconds 10 20-08-06
21-07
08 Preset dial display hold time 0-64800 Seconds 10 20-08-09
21-11
09 Ringdown Extension Timer
A Ringdown extension automatically calls its
programmed destination after this interval.
0-64800 Seconds 5 20-08-09
20-31-06
21-11
10 Dial Digits for Toll Restriction Path
If this option is programmed with an entry
other than “0”, a call will not have a talk path
for the time defined in 21-01-11 unless the
user dials at least the number of digits entered
in this option when placing an outgoing call.
This means that an entry of 4 or higher in this
program will cause a problem when dialing
911. Since it is only a 3-digit number, the call
will not have a talk path, preventing the emer-
gency dispatcher from hearing the caller. It is
recommended that this option be kept at its
default setting of “0” to prevent any problems
with dialing 911.
0-24 0 21-01-11
11 Inter-Digit Time for Toll Restriction Path
Control
For analog trunks only, if a user does not dial
the minimum number of digits for an outgo-
ing call (as defined in 21-01-10), determine
how long the talk path will be delayed for the
call. The transmit speech path is disconnected
to prevent a user from placing a DTMF tone
dialler to the mic and bypassing Toll Restric-
tion and SMDR.
0-60 0 21-01-10
12 Dial 911 Routing Without Trunk Access
If enabled (1), an extension user can dial 911
without first dialing a trunk access code or
pressing a line key. If disabled (0), an exten-
sion user must dial a trunk access code (e.g.,
9) or press a line key before dialing 911.
0 = Trunk Access Code
Required
1 = Trunk Access Code
Not Required
1
13 Alarm Ring Timer (E911)
Use this option to set the duration of the E911
Alarm Ring Time. If set for 0, the E911
Alarm will ring for 60 seconds.
0, 1-64800 Seconds
(0 = 60 Seconds)
0 11-12-56
20-08-16
14 Forced Account Code Inter-digit Timer
The UX5000 waits this interval for a user to
enter a Forced Account code.
0-64800 Seconds 3
Item
No.
Item Input Data Default Related Program