System information

Program 20 : System Option Setup
20-31 : Timer Data
354 Programming UX5000 Software Program Manual
07 22-01-03 Trunk Timer Class of
Service
Ring No Answer Alarm Time
If a trunk rings a key terminal longer than this
interval, the UX5000 changes the ring cadence.
This indicates to the user that the call has been
ringing too long.
60 0-64800
08 22-01-04 Trunk Timer Class of
Service
DIL/Incoming Ring Group
No Answer Time
A DIL that rings its programmed destination
longer than this interval diverts to the DIL No
Answer Ring Group (set in Program 22-08).
0 0-64800
09 22-01-06 Trunk Timer Class of
Service
DID Ring-No-Answer Time
In UX5000s with DID Ring No Answer Inter-
cept, this interval sets the Ring No Answer time.
This interval is how long a DID call rings the
destination extension before rerouting to the
intercept ring group.
20 0-64800
10 24-01-01 Extension Timer Class
of Service
and
Extension’s Class of
Service
Hold Recall Time
(Non exclusive Hold)
A call on Hold recalls the extension that placed
it on Hold after this interval.
90 0-64800
11 24-01-02 Extension’s Class of
Service
Hold Recall CallBack Time
(Non exclusive Hold)
A trunk recalling from Hold an extension for
this interval.
30 0-64800
12 24-01-03 Extension Timer Class
of Service
and
Extension’s Class of
Service
Exclusive Hold Recall Time
A call on Hold recalls the extension that placed
it on Hold after this interval.
90 0-64800
13 24-01-04 Extension’s Class of
Service
Exclusive Hold Recall Callback Time
An Exclusive Hold Recall rings an extension for
this interval. If not picked up, the call goes back
on non-exclusive Hold.
30 0-64800
14 24-01-06 Extension Timer Class
of Service
and
Extension’s Class of
Service
Park Hold Time – Normal
A call left parked longer than this interval
recalls the extension that initially parked it.
90 0-64800
15 24-02-03 Extension Timer Class
of Service
Delayed Call Forwarding Time
If activated at an extension, No Answer Call
Forwarding occurs after this interval.
10 0-64800
Class of Service Timer Data, Program 20-31
Item
Default:
Class 0
Follows
Program
Type Timer Default
Input
Data