System information

Program 10 : System Conguration Setup
10-03 : Blade Setup
UX5000 Software Program Manual Programming 21
For TLIU Blade
For BRIU Blade
Physical Port Number 01-04
Item
No.
Item Input Data Default
01 Logical Port Number 0-200 0
02 2/4Wire 0 = 2Wire
1 = 4Wire
1
03 E&M Line Control Method
M-Lead Type
0 = Type I
1 = Type V
1
ISDN Line Number 01-04
Item
No.
Item Input Data Default
01 ISDN Line Mode 0 = No Setting
1 = T-Bus
2 = S-Bus
Options 3-5 determines the clock source
for the networked connection.
3 = Network Mode (Leased Line)
Telco sends the clock to the Master System
Telco sends the clock to the Slave System
4 = Network Mode (Interconnected Line)
Master System sends the clock to the Telco (or direct
connection without telco) which then sends the clock
to the Slave System
5 = Network Mode (Interconnected Line, Fixed layer 1=NT)
Master System sends the clock to the Telco
Slave System sends the clock to the Telco
6 = S-Point (Leased Line)
1
02 Logical Port Number
(see Note 1)
0 = No Setting
1 = For T-Bus (1-200)
2 = For S-Bus (1-512)
3 = Network Mode
4 = Network Mode
5 = Network Mode
6 = For S-Bus (Leased Line) (1-512)
0
03 Connection Type 0 = Point-to-Multipoint (not available for CygniLink)
1 = Point-to-Point
0
04 Layer 3 Timer Type (see Note 2) 1-5 1