System information

Program 20 : System Option Setup
20-18 : Service Tone Timers
334 Programming UX5000 Software Program Manual
20-18 : Service Tone Timers
Description
Use Program 20-18 : Service Tone Timer to set the values for the UX5000 service tone timers.
Refer to the following chart for a description of each option, its range and default setting.
Input Data
Level:
Feature Availability
IN Available.
Item
No.
Item Input Data Default Description
Related
Program
01 Extension Dial Tone
Time
0-64800 seconds 30 After getting Intercom dial
tone, a keyset user has this
interval to dial the rst digit of
the Intercom call.
02 Busy tone timer 0-64800 seconds 15
03 Congestion tone 0-64800 seconds 10 A Busy Tone when UX5000
resources run short. (such as
DTMF receiver resources)
04 Call Waiting Tone
Timer
0-64800 seconds 10 This option sets the interval
between Call Waiting tones.
This timer also sets the inter-
val between Off Hook Signal-
ing alerts.
05 Keyset Conrmation
Tone
0-64800 seconds 10
06 Interval of call wait-
ing tone
0-64800 seconds 10 Determine the interval
between Call Waiting tones. If
set to “0”, the tone will only
be heard once.
07 Intrusion Tone
Repeat Time
0-64800 seconds 0 After a call is interrupted
(such as Barge In, Voice Mail
Conversation Recording,
Voice Over, etc), the UX5000
repeats the Intrusion Tone
after this interval. Normally,
you should enter 0 to disable
this interval.
08 Conference Tone
Interval
0-64800 seconds 0