System information

Program 16 : Department Group Setup
16-01 : Department Group Basic Data Setup
UX5000 Software Program Manual Programming 281
Program 16 : Department Group Setup
16-01 : Department Group Basic Data Setup
Description
Use Program 16-01 : Department Group Basic Data Setup to set the function mode for each
department group.
Input Data
Level:
Feature Availability
IN Available - 64 Department Groups.
Department Group Number 01-64
Item
No.
Item Input Data Default
Related
Program
01 Department Name
Enter the Department Group name to
be displayed when the group number is
called.
Max. 12 characters No setting 11-07
02 Department Calling Cycle
Use this option to set the call routing
for Department Calling. Routing can
be either circular (cycles to all termi-
nals in group) or priority (cycles to
highest priority extensions rst).
0 = Priority Routing
1 = Circular Routing
0 16-02
03 Department Routing When Busy
Use this option to set how the UX5000
routes an Intercom call to a busy
Department Group member. Intercom
callers to the extension can either hear
busy or route to the rst available
department number. This only occurs
for calls to the extension directly, not
the department number assigned in
Program 11-07
0 = Normal (Intercom caller to busy
department member hears busy)
1 = Circular (Intercom callers to busy
department member routes to idle
member)
0 16-02
04 Hunting Mode
Use this option to set the action taken
when a call reaches the last extension
in the Department Group (0=hunting
stopped, 1 =hunting repeats with circu-
lar routing through the Department
Group.
0 = Last extension is called and hunting
is stopped.
1 = Circular
0