System information

Program 15 : Extension, Basic Setup
15-05 : IP Terminal Basic Data Setup
244 Programming UX5000 Software Program Manual
Conditions
None
Feature Cross Reference
VoIP
Terminal Programming Instructions
To enter data for Program 15-05 (IP Terminal Basic Data Setup):
1. Enter the programming mode.
2. 15 05
3. Enter the number of the item you want to program.
4. Enter the terminal number to be dened or press FLASH to use the displayed entry.
5. Enter data for the item you selected + HOLD.
6. Enter data for the next item in the program.
OR
Press MIC once to enter a new item number.
OR
Press MIC until you’ve exited that series’s programming section.
31 Warning Sound While Talking
Determine if a warning tone is allowed while
active on a call.
0 = Disable
1 = Enable
1
32 Key Reading Out Function
Determine if this feature is enabled.
0 = Disable
1 = Enable
0
33 LAN Side IP Address
- View Only -
0.0.0.0 ~ 255.255.255.255 0.0.0.0
34 Touch Panel On/Off
Determine if the touch panels on the IP CTS
terminals are enabled for an extension user.
0 = Disabled
1 = Enabled
1
15-05-01 TEL301
IP-Phone Type 0:NGT
back
↑ ↓ select
15-05-nn TELnnn
nnnnn
← − + →
Item
No.
Item Input Data Default
Related
Program