System information
Program 12 : Night Mode Setup
12-01 : Night Mode Function Setup
UX5000 Software Program Manual Programming ◆ 165
Program 12 : Night Mode Setup
12-01 : Night Mode Function Setup
Description
Use Program 12-01 : Night Mode Function Setup to set up the Night Mode options. Refer to the
following chart for a description of each option, its range and default setting.
Input Data
Note: Even if the operation mode is changed manually, the operation mode changes according to
the schedule set up.
Conditions
None
Feature Cross Reference
● Night Service
Level:
Feature Availability
IN • Available.
Item
No.
Item Input Data Default Description
Related
Program
01 Manual Night Service
Enable
0-off
1-on
1 Allows/prevents users from activating
Night Service by dialing a service
code.
11-10-01
02 Automatic Night Service 0-off
1-on
0 According to a preset schedule, enable
or disable Automatic Night Service for
the UX5000.
12-02
12-03
12-04
03 Night Mode Switch
Operating Mode
(Sensor switch on CPU
only)
0-disable
1-8
(operation mode)
0 Use this option to set the operation
mode of the CPU Night Service mode
switch sensors (external Night Mode
Selector Switch). The Night Service
mode affects trunk inbound and out-
bound routing.
Note: Function keys 1-8 can be used
to select the input data 0-Mode 7, but
to select Mode 8, the digit ‘8’ on the
dial pad must be pressed instead.
04 General Purpose
Contact Detector
0=Not Used
1-1=Detector
Number
0 Set the detection circuit of the general
purpose relay of the 2PGDAD when
switching night mode (Program
10-41).
10-41