System information
Program 90 : Maintenance Program
90-58 : Restore Recovery Data
992 ◆ Programming UX5000 Software Program Manual
90-58 : Restore Recovery Data
Description
Use Program 90-58 : Restore Recovery Data to restore the UX5000 data from a file preserved in
the flash memory on the CCPU (saved in Program 90-57). After executing the command, the
UX5000 restarts automatically.
Input Data
Conditions
● It is recommended to back up the UX5000 data to a USB thumb drive using Program 90-03 as
the recovery data cannot be transferred to another UX5000.
● The process of data recovery takes approximately 90 seconds.
● A UX5000 reset is automatically performed after the data recovery process.
Feature Cross Reference
Maintenance
Level:
Feature Availability
SA • Available.
Data ID 1-5
Item No. Item Input Data Default
01 Restore and Reset Data Dial 1 + Hold Key
(To cancel, press hold key with-
out dialing 1)
-