Program 10 : System Configuration Setup
10-32 : PRI Networking Channel Limitation
84 ◆ Programming UX5000 Software Program Manual
10-32 : PRI Networking Channel Limitation
Description
Use Program 10-32 : PRI Networking Channel Limitation to assign the number of B-channels
to be used for each ISDN blade. This allows for fractional PRIs when used with multiple site net-
working. If this program is limited to less than "23" on one side of the network, then it also limits
both inbound and outbound network calls. For example, when you select 10 channels then only
channels 1 to 10 will be available. If a call is attempted on channels 11 to 30 the caller will receive
busy tone. This also applies on the other side of the network as well.
The setting is for each slot within the UX5000; ensure that you select the correct slot before making
any changes.
This program will not affect a PRI card set as Trunk or Station mode.
Input Data
Conditions
None
Feature Cross Reference
Networking - AspireNet
Level:
Feature Availability
IN • Available.
Slot Number 1 - 24
Item
No.
Item Input Data Default
Related
Program
01 Maximum Channels
Set the maximum number
of channels which can be
used with PRI CygniLink.