Specifications
3-10
VOLUME LOGGING RUN STATUS SCREEN INPUTS
Page down from the QUEUE DETECTORS status screen, Prior Menu…selection 8…….
or…hit MAIN MENU-RUN MODE—RUN MODE DISPLAY
—I/O STATUS—DETECTORS (MAIN MENU-1-1-6-6-PGDN The input status screens display the current activity
5 times) to get…. all physical inputs. Since inputs can be “AND”ed
and/ “OR”d with other inputs and outputs, the
activity of those associated inputs is also displayed.
An asterisk (*) indicates activity. See Application
Chapter for complete definitions. PAGE DOWN
through several screens of the following list of
inputs:
PG DWN ETC. through detectors 5-64.
Function Description
The top row of the display shows the number of re-
cords available for the T1 (telephone 1) and the T2 VD1-32 Vehicle detectors 1-32
(telephone 2) buffers and the total. The volume counts PED1-8 Pedestrian detectors 1-8
are per the sample period, i.e. they zero out at the beginning HLD1-8 Phase hold 1-8
of each new sample period. A volume log sample period VOM1-8 Vehicle phase omit 1-8
must be programmed to produce counts. POM1-8 Pedestrian phase omit 1-8
PRE1-6 Pre-empts 1-6
TIME CLOCK CIRCUIT STATUS WRM Walk rest modifier
MRCL Min recall
The screens appear as shown below, are accessed SG/CS Simultaneous gap-out inhibit/
through the I/O STATUS DISPLAYS menu or PG DWN Conditional service
from the Detector Volume Logs. WP10 Call to week program 10
ASQA-D Alternate sequence A-D
MCE Manual control enable
IADV Interval advance
EXST External start
TSTA-C Test A, B, or C
DIM Dimming function
LAMP Indicator lamp control
X= CKT is on MONA-C Conflict monitor status bits A-C
MONF Malfunction Management Unit flash
PG DWN…. LCFL Local flash
FLM1-2 Flash monitor 1 & 2
PLANA-D Timing plan A-D
OFF1-3 Offset1-3
TBC Call to clock
CTF Call to free
SNCI Sync inhibit
CSYS Call to system
X=CKT is on TSNC Time clock sync
ITCI Interconnect inhibit
Etc…Continue paging down through all circuits. Refer to AUTF Automatic (remote) flash
CLOCK CIRCUIT DESCRIPTIONS in TIME CLOCK CNA1-2 Call to non-actuated 1-2
PROGRAMMING Section. FRC1-2 Force-off ring 1 & 2
IMX1-2 Inhibit MAX timing ring 1 & 2
MX21-2 MAX timing ring 1 & 2
ORC1-2 Omit red clearance ring 1 & 2
PCY1-2 Pedestrian re-cycle ring 1 & 2
RRM1-2 Red rest ring 1 & 2
STM1-2 Stop time ring 1 & 2
UDA User defined 1-8
ADR0-7 Address bits 0-7
VD33-64 Vehicle det’s 33-64 (not used)
# REC S AVAIL: T1: 0 T2: 0 TOT: 0
DET INP 1 2 3 4
VOL 0 0 0 0
--PGDN TO CONTINUE--
-TIME CLOCK CKT RUN MODE--(X=CIRCUIT ON)
CKT 8 9 10 11 12 13 14 15
FUNCT FL AX1 AX2 AX3 AX4 SYS MX2 IM1
STAT X
X X
-TIME CLOCK CKT RUN MODE--(X=CIRCUIT ON)
CKT 16 17 18 19 20 21 22 23
FUNCT IM2 CN1 CN2 MIN VC1 VC2 VC3 VC4
STAT X