Specifications

3-6
SYSTEM MODE……Indicates system mode/status:
IN SYSTEM: INTERCONNECT MODE
IN SYSTEM: TBC MODE
IN SYSTEM: TBC, LOST CARRIER
IN SYSTEM: TELEMETRY
FREE: NO SYNC PULSE YET
FREE: LOST SYNC PULSE
FREE: COMB CSO TO FREE
FREE: TBC, LOST CARRIER
FREE: NO CALL FOR SYSTEM
FREE: MANUALLY PROGRAMMED
FREE: MANUAL CONTROL ACTIVE
FREE: FLASH COMMAND ACTIVE
FREE: PRE-EMPTION ACTIVE
FREE: CALL TO FREE, INPUT/CLOCK
VOLUME DENSITY STATUS DISPLAY
PG DWN OR.PRIOR MENU..Selection 4...VOL/DENS
Left side is Ring 1, right side is ring 2.
PHASE X, Y………Current phases ring 1 and 2
INIT XY……..….…. Initial green (min green) timing:
INIT XY = Nominal min green setting
VINIT XY = Variable Initial in effect
MAX XY…………...Max timer timing
TBR XY……………Time before reduction timer timing
TTR XY……………Time to reduce timer timing
PSG XY……………Passage timer timing
CURRENT GAP….Any of the following may appear:
CURRENT GAP XY = Current Value of passage
CNA MODE = Phase in CNA mode, gap is N/A
MAX REC = Phase in Recall Max, gap is N/A
PED TIMING = Phase in Ped timing, gap is N/A
TIME CLOCK EVENT STATUS
PG DWN OR…PRIOR MENU…Selection 5…
This section consists of two types of status; the first is
the clock event status, which shows the time, date,
service, and max plan called for, as well active clock
CSO (see note). The second type of status shows the
active state (on or off) of each the numerous clock
circuits.
NOTE: Time clock circuit status screens can be found
in sub-menu (8) under I/O status.
SELECTION 1….TIME CLOCK EVENT STATUS…...
TIME, DATE
……..Time of day, date of year displayed
Week 1-53
…..…...Week of year displayed; 01 = week
of Jan 1, etc.
WEEK PROG 1-10
.Week program currently in effect
DAY WXY
…….…..Day of week: MON, TUE, WED, etc.
DAY PRG 1-15
….Day program currently in effect
SPO-8
……………Service Plan 0-8 (as called by clock)
MPO-8
……………Max Plan 0-8 (as called by clock)
C/S/O
…………….Clock event cycle, split, and offset.
Note: This is the Clock event cycle, split, offset
selection and is the actual C/S/O in effect only if the
mode is time clock or manual. The C/S/O indictions
will match the manual mode selections when in the
manual mode (manual overrides clock).
MODE XX XXX……Indicates the selection mode,
where:
M= Manual
T= Telemetry
C= Clock (TBC)
I= Interconnect
L= Local Split Selection (adaptive split)
S= Cycle/Split
Note: The time clock event selections (directly above
the mode indications) are the actual C/S/O in effect
only if the mode is clock or manual.
I/O STATUS
This section provides active status of all LMD inputs
and outputs in terms of the controller’s perception of
such status.
PG DWN..OR.PRIOR MENU...Selection 6…I/O Status
PHASE 2 INIT 5 | PHASE 6 INIT 5
MAX 2 TBR 12 | MAXD 2 TBR 12
TTR 0 PSG 4 | TTR 0 PSG 4
CURRENT GAP 2 | CURRENT GAP 2
TIME: 16:04:33 DATE: 08/14/90
WEEK |WK PROG|DAY |DY PRG |SP|MP|C/S/O
22 | 1 |THU | 1 |1 |1 |1 1 1
MODE: C C C C C