Specifications
Copyright Peek Traffic Systems Incorporated, 2000
22
REPORTS SET-UP
FUNCTION SCHEDULING (MM-2-7-1-PgDn, etc.)
FUNCT UD1 UD2 UD3 UD4 UD5 UD6 UD7 UD8
MODE
FUNCT CLK PWR FRM MMU CHK DET RFL MCE
MODE
FUNCT HPE CYC CRD KEY SYS FLM LPE MOE
MODE
Mode range: 0 = none, =1 - 3 = Sched A, B, C, 4 = request
VOLUME LOG SET-UP (MM-2-7-2)
NORM For either: 0 = disable, 1, 5, 6, 10, 15, 30, or 60
ALT = sampling period in minutes, 99 = by cycle
Alternate sampling period selected by clock ckt 136
DET’s ENABLED FOR VOL LOGGING (MM-2-7-1-PgDn, etc.)
DET 1 2 3 4 5 6 7 8
MODE
DET 9 10 11 12 13 14 15 16
MODE
DET 17 18 19 20 21 22 23 24
MODE
Mode = ON/OFF, ON = Det will log, OFF = No logging
MOE AND SPEED LOG SET-UP (MM-2-7-3)
NORM For either: 0 = disable, 5, 6, 10, 15, 30, or 60
ALT = sampling period in minutes
TRAP 0 - 255; Discard speeds above this value
Alternate sampling period selected by clock ckt 140
TRUE SPEED TRAP SET-UP (MM-2-7-3-PgDn)
SPEED TRAP A B C D
DETECTORS 9/10 11/12 13/14 15/16
DISTANCE
UNITS
Distance range: 0-255 units. Units: 0=Inches, 1=Feet, 2=Cent. 3=Decim.
COMPUTED SPEED DET SET-UP (MM-2-7-3-PgDn, etc.)
DET 1 2 3 4 5 6 7 8
TIME
DET 9 10 11 12 13 14 15 16
TIME
DET 17 18 19 20 21 22 23 24
TIME
Time range; 0 - 255 hundredths of a second. Compute time based on ave
veh at 30 MPH (50 KPH) over loop. For example, an average vehicle (16’ )
would occupy a 6’ x 6’ loop for 44’/sec divided by (16’+6’) = 50 hundredths.
MOE VOL/OCC DET ASSIGNMENTS (MM-2-7-3-PgDn, etc.)
DET 1 2 3 4 5 6 7 8
MOE PH
DET 9 10 11 12 13 14 15 16
MOE PH
DET 17 18 19 20 21 22 23 24
MOE PH
MOE Phase range; 0 - 8. Assigns detectors to phases for MOE logging so that
volume and occupancy counts can be tabulated on a per phase basis.
CALL IN DELAY SET-UP (MM-2-7-4)
SCHEDULE A B C VOLUME
DELAY TIME
Delay range: 0- 255 minutes. Delays prevent repeated call-ins over a short
period due to multiple events. By delaying, the unit will tend to collect data for
a while then call it all in at once.