Specifications
Copyright Peek Traffic Systems Incorporated, 2000
19
SPECIAL INTERVALS (MM-2-5-7) (BLANK = DEFAULT = CODE 5 = RED)
SPEC. INTERVAL PH1 PH1 PH2 PH3 PH4 PH5 PH6 PH7 PH8 OL A OL B OL C OL D
.1
.2
.3
.4
.5
.6
.7
.8
.9
Phase and Overlap color codes 0 = Dark 3 = Flashing Don’t Walk 6 = Flash Yellow Wig 9 = Flash Red Wag
1 = Green/dw 4 = Yellow 7 = Flash Yellow Wag . = Fast Flash green
2 = Green/walk 5 = Red 8 = Flash Red Wig
Notes: 1. “Wig” and “Wag” are 180 degrees out of phase w/each other
2. Must enter special intervals from all red, i.e. “90” code must
precede first special interval. The last interval must be all 5’s.
HI PRIORITY PRE-EMPT SET-UP
PE MEMORY/DELAY/RE-SERVICE (MM-2-5-8-1)
PE INPUT 1 2 3 4 5 6
MEMORY (ON/OFF)
DELAY BEFORE PE
MIN RESEVICE
Delay Range = 0-255 Seconds, Reservice = 0 - 99 Minutes
PE OVERLAP INHIBITS (MM-2-5-8-2)
PE INPUT 1 2 3 4 5 6
Use 4 digit code for each input in order of ABCD
0 = Allow normal overlap
1 = Inhibit overlap on entry into and during pre-empt
Example: 0100 = Inhibit OL/B
PRE-EMPT ENTRY TIMES (MM-2-5-8-3)
PE INPUT MGR WLK PCL OLY OLR FDW/Y
1
2
3
4
5
6
Range: 0 - 9.9 or 127 for MGR, WLK, PCL, OLY, OLR. FDW/Y = ON OFF
Note:
“0” for MGR, WLK, PCL = Use normal phase time values. Thus, “.1” is the
shortest programmable PE entry time for these values.
OLY, OLR = Overlap yellow & red time when OL must time its own clearance.
FDW/Y= ON = Allow Don’t Walk to flash through yellow on entry into P
E.
PRE-EMPT PRIORITIES (MM-2-5-8-4)
PE INPUT 1 2 3 4 5 6
PRIORITY
OVERRIDE FLASH
Priority = 1-6 (1 = highest, 6 = lowest). When equal, 1st come 1st serve.
Override Flash = ON/OFF. ON = Exit remote (UCF) flash for pre-empt.