Specifications

Copyright Peek Traffic Systems Incorporated, 2000
8
COORDINATION
COORD MODES (MM-2-3-1) Determines selection mode
FL ON/OFF 9=TC 10=INT 11=COM 12=AU
SYS ON/OFF 9=TC 10=INT 11=COM 12=AU
CYC 1-8=MAN 9=TC 10=INT 11=COM 12=AU
SPL 1-4=MAN 9=TC 10=INT 11=COM 12=AU
OFF 0-5=MAN 9=TC 10=INT 11=COM 12=AU
OFFSET SEEKING MODE (MM-2-3-2)
SEEKING MODE 0 =Manual resync (hit clr in coord run screen)
1 =Dwell, 2 = shortway, 3 = interrupter
COORD OPTIONS
OPERATIONAL (MM-2-3-3-1)
FLOAT
F.O’S
LOSS SYNC
TO FREE
SYS TO
MX2 CNA
CSO /
FREE
SCM
MODE
WALK
ADJ
All options ON or OFF except CSO/Free which is 0 or 111 - 956 (don’t cares)
Floating force offs = 3 = Special code, fixed F.O. but no CNA ph force offs
CSO TO LEAD/LAG PATTERNS (MM-2-3-3-2)
SEQ CSO 1 & 2 3 & 4 5 & 6 7 & 8
1 1 = ODD
2 LEADS
3
4 2 = ODD
5 LAGS
6
7 9
,
5
,
6 =
8 Don’t care
9 states for
10 C
,
S
,
O
ADAPTIVE SPLIT (MM-2-3-3-3-PgDn, etc.)
CYCLES Number of c
y
cles used
p
er ada
p
tive s
p
lit sam
p
le
MODE How Ad. s
p
lit selected: 0=Queues
,
1=Force offs
THRSH Min # of
q
ueues or force offs to select new s
p
lit
Note: Floating force offs cause force off values to act like max times, not
points in cycle. SCM causes cycle timer to stop & wait if phase can’t be forced
off--like when a ped is timing. Walk adjust causes the unit to “look ahead,” to
see if the ped will terminate before the force off point. If not (like when offset
seeking), it will shorten the walk as needed, to as low as 10 sec.
ADAPTIVE SPLIT TO PHASE ASSIGNMENTS (MM-2-3-3-3-PgDn, etc.)
SPL /PH
φ1 φ2 φ3 φ4 φ5 φ6 φ7 φ8
0 =Not
1 considered
2
3 1 =Selected
4 phases
QUEUE DETECTOR TO PHASE ASSIGNMENTS (MM-2-3-3-3-PgDn, etc.)
PHASE 1 1 2 2 3 3 4 4
Q. DETECTOR
Q. DELAY
PHASE 5 5 6 6 7 7 8 8
Q. DETECTOR
Q. DELAY
Q DET Ranges: Q detector =1-24, Q delay = 0-9.9 or 127,
ADAPTIVE SPLIT INHIBITS (MM-2-3-3-3-PgDn, etc.)
CYC 1
O1 O2 O3 Q4 O5
CYC 5
O1 O2 O3 O4 O5
SPL 2
SPL 2
SPL 3
SPL 3
SPL 4
SPL 4
CYC 2
O1 O2 O3 Q4 O5
CYC 6
O1 O2 O3 O4 O5
SPL 2
SPL 2
SPL 3
SPL 3
SPL 4
SPL 4
CYC 3
O1 O2 O3 Q4 O5
CYC 7
O1 O2 O3 O4 O5
SPL 2
SPL 2
SPL 3
SPL 3
SPL 4
SPL 4
CYC 4
O1 O2 O3 Q4 O5
CYC 8
O1 O2 O3 O4 O5
SPL 2
SPL 2
SPL 3
SPL 3
SPL 4
SPL 4
0 = No inhibit, 1 = inhibit (do not allow split to be selected during that cyc & offset)