Specifications
Copyright Peek Traffic Systems Incorporated, 2000
4
SERVICE PLANS (MM-2-2-6-5-1-PgDn. etc.)
Called by Clock or Cyc/Spl (plans override normal call modes, min grn, etc.)
SERVICE PLAN # 1
SERVICE PLAN # 4
SERVICE PLAN # 7
PHASE 1 2 3 4 5 6 7 8 PHASE 1 2 3 4 5 6 7 8 PHASE 1 2 3 4 5 6 7 8
CALL MODE CALL MODE CALL MODE
MIN GRN MIN GRN MIN GRN
PASSAGE PASSAGE PASSAGE
WLK WLK WLK
PED CLR PED CLR PED CLR
SERVICE PLAN # 2
SERVICE PLAN # 5
SERVICE PLAN # 8
PHASE 1 2 3 4 5 6 7 8 PHASE 1 2 3 4 5 6 7 8 PHASE 1 2 3 4 5 6 7 8
CALL MODE CALL MODE CALL MODE
MIN GRN MIN GRN MIN GRN
PASSAGE PASSAGE PASSAGE
WLK WLK WLK
PED CLR PED CLR PED CLR
SERVICE PLAN # 3
SERVICE PLAN # 6
SERVICE PLAN CALL MODES
PHASE 1 2 3 4 5 6 7 8 PHASE 1 2 3 4 5 6 7 8 0 = OMIT 6 = PED RECALL
CALL MODE CALL MODE 1 = ACTUATED 7 = PED OMIT
MIN GRN MIN GRN 2 = CNA
PASSAGE PASSAGE 3 = RECALL EXT. Note: Service plans called
WLK WLK 4 = MAX RECALL by clock ckt or Cyc/split.
PED CLR PED CLR 5 = SOFT RECALL Cyc/spl overrides clock
NOTES
Each Service Plan used must be filled out entirely even if only one parameter is
to be different from standard. All parameters indicated are invoked when the
service plan is. Also note that if the call mode is “0,” the phase will be omitted.
Value ranges: Call mode: 0-7 (see chart above) WLK: 0-9.9 or 127
MGR: 0-9.9 or 127 PCL: 0-9.9 or 127
PSG: 0-9.9 or 127