Specifications
Copyright Peek Traffic Systems Incorporated, 2000
3
RED REVERT, PED OPTIONS, INCREASE YEL & RED (MM-2-2-6-2)
RED
REVERT
PED
ENHANCE
MENT
FDW
THRU
YEL
AUTO
PED
CLEAR
% CKT 148
INC’S
Y & R
TEST
B
+ 2
Red revert : Amount of red clear when phase “backs-up” on itself (+ 2 secs )
Ped Enhance: OFF = Normal walk time always used
ON = Normal walk time used if in CNA mode, max time used if not
FDW Thru Yel: OFF = Normal Flashing Don’t Walk (goes solid when yellow starts)
ON = FDW continues thru yellow (time is added to PCL setting)
Auto Ped Clr: OFF = MCE does not protect ped clearances
ON = MCE does protect ped clearances
% Incr. Y & R: % amount Yellow & Red will be increased when clk ckt 148 is on
Test B input: Input used as: 0= DIM, 1= Call to free op, 2 = Call to free op after 3
minutes if input stays on
PED OVERLAPS (MM-2-2-6-2-PgDn)
PHASE
φ
1
φ
2
φ
3
φ
4
φ
5
φ
6
φ
7
φ
8
PH 1 PED
PH 2 PED
PH 3 PED
PH 4 PED
0 = NO PED
PH 5 PED
1 = PED O/L
PH 6 PED
PH 7 PED
PH 8 PED
Allows peds to overlap phases. When a ped call exists, walk is initiated in 1st ped
phase. If ped call exists on next overlapping ped phase, walk will be maintained into
next phase, timing walk then ped clear if necessary in that phase.
0 = No overlap ped (note: if all 0’s, ped is standard phase ped)
1 = Corresponding column phase is ped overlap parent phase
DUAL ENTRY (MM-2-2-6-3)
PHASE
φ
1
φ
2
φ
3
φ
4
φ
5
φ
6
φ
7
φ
8
DUAL ENTRY PHASE
DUAL ENTRY MODE (MM-2-2-6-3-PgDn)
MODE
1 = OFF 3 = Called by CNA 5 = Called by Input
2 = ON 4 = Called by system
CONDITIONAL SERVICE/RE-SERV (MM-2-2-6-3-PgDn-PgDn)
PHASE
φ
1
φ
3
φ
5
φ
7
MODE
Mode range = 0-5 (see below)
C.S. MAX
C.S MAX = 0 - 99 secs
CS = Conditional Service, RS = Re-service (back to opposing thru after CS phase)
Mode:
0 = Both CS and RS OFF 3 = CS If not system
1 = CS ON 4 = Both ON
2 = CS by clock or input 5 = RS by clock or input
CS Max value determines if CS phase serviced, then acts as CS Max when green.
CS phase serviced if opposite thru phase gap’s out when adjacent thru Max Time.
Remaining >
(Opposite Thru Clearance + CS MAX).
5 SECTION HEAD RESTRICTIONS (MM-2-2-6-4)
2 0MIT 5 4 0MIT 7 6 0MIT 1 8 0MIT 3
ON or OFF
5 SECTION HEAD YELLOW BLANKING (MM-2-2-6-4-PgDn)
PHASE
φ
1
φ
3
φ
5
φ
7
ON = Blanks yellow if clearing
ON or OFF
with adjacent through
NOTES