OVERLAPS AND CONTROLLER OPTIONS
SET OVERLAPS (MM-2-2-5-1)
PHASE
φ1
φ2
φ3
φ4
φ5
φ6
φ7
φ8
O/L A
0 = No Overla
p
O/L B
1 = Standard
O/L C
2 = Fast FL O/L
O/L D
3 = Not Ped O/L
DELAYED OVERLAPS AND ADVANCED WARNING (MM-2-2-5-2)
DEL YEL RED CPH/OL AW ADD
O/L A
/
O/L B
/
O/L C
/
O/L D
/
DEL = Amount O/L yel delayed after parent ph (or advance warning time if used)
YEL = Yellow clearance for delayed O/L
RED = Red clearance for delayed O/L
CPH-OL = Conditional phase/O/L, used in advance warning if another phase or O/L
would normally clear together with this O/L but has a longer delay (shorter
advance assigns longer as conditional ph/O/L).
AW = 0 = Advance Warning not used (disabled), 1 = AW used (enabled)
ADD = Advance warning De-activation Delay; amount into green before warning
signal shuts off (allows for Q’s to exhaust after light turns green).
OVERLAP INHIBITS (MM-2-2-5-3)
PH-O/L
φ1
φ2
φ3
φ4
φ5
φ6
φ7
φ8
A B C D
O/LA GRN
O/LA YEL
O/LA RED
O/LB GRN
O/LB YEL
O/LB RED
O/LC GRN
O/LC YEL
O/LC RED
O/LD GRN
O/LD YEL
O/LD RED
Apply code to inhibit indicated O/L colors:
0 = No Inhibit 3 = Inhib during red clr 6 = Inhibit during grn, yel, red clr
1 = Inhibit during green 4 = Inhib during grn & yel 7 = Inhibit during wlk & ped clr
2 = Inhibit during yellow 5 = inhib during yel & red clr
FAST FLASH RATE (MM-2-2-5-4)
IN FPM: 0 = 6O, 1 = 120, 2 = 150, 3 =180
OVERLAP CARD (MM-2-2-5-5...Display only & only if O/L card installed)
O/L A
PHASES
O/L B
PHASES
O/L C
PHASES
O/L D
PHASES
PHASES AS OVERLAPS and ADVANCED WARNING (MM-2-2-5-6)
PH
1 2 3 4 5 6 7 8
DEL CPH/OL AW AD
1
/
2
/
3
/
4
/
5
/
6
/
7
/
8
/
Row phase is phase as O/L, column phases are overlapping phases, where;
0 = No overlap (all 0’s indicates row phase is a normal, non overlapping phase)
1 = Overlapping phase
.0 In delay column = Fast flash the overlap green
CONTROLLER OPTIONS
LAST CAR PASSAGE (MM-2-2-6-1)
ON REDUCED GAP OUT THE UNIT WILL
1 = Recall phase, 2 = Last Car Passage, 3 = Terminate normally
SIMULTANEOUS GAP OUT INHIBIT (MM-2-2-6-1- PgDn)
PHASE
φ1
φ2
φ3
φ4
φ5
φ6
φ7
φ8
CODE
0 = Passage can reset, 1 = passage cannot reset, 2 = input decides
DIMMING (MM-2-2-6-1-PgDn-PgDn)
PH-O/L
φ1 φ2 φ3 φ4 φ5 φ6 φ7 φ8
A B C D
RED
YEL
GRN
WLK
-- -- -- --
DW
-- -- -- --
PCL
-- -- -- --
0 = No Dim, 1 = Dim + half wave, 2 = Dim - half wave