Specifications

Copyright Peek Traffic Systems Incorporated, 2000
1
MEMORY/RECALL/CNA (MM-2-2-1) Function values: ON or OFF
φ1 φ2 φ3 φ4 φ5 φ6 φ7 φ8
MEMORY
EXT RECALL
MAX RECALL
PED RECALL
CNA I
CNA II
FLASH WALK
SOFT RECALL
ACT WALK REST
COND. PED
FWTPCL
PHASE TIMING (MM-2-2-2)
φ1 φ2 φ3 φ4 φ5 φ6 φ7 φ8
MIN GREEN
PASSAGE
YELLOW
RED CLEAR
MAX 1
MAX 2
WALK
PED CLEAR
S/A
TBR
TTR
MIN GAP
MAX VI
MAX EXTEND
AUTO MAX
ADDED MAX RED
Range: 0-9.9 or 127 except max times and auto max which are 0-255 secs
INITIALIZE/FLASH (MM-2-2-4)
1 = RED, 2 = YEL, 3=GRN
INITIALIZE ENTER FL EXIT FLASH
RING 1 PHASE
RING 2 PHASE
INTERVAL
1
NOTE: Enter flash interval is permanently set to 1 (RED)
POWER-UP RESTART TIMINGS (MM-2-2-4-PgDn)
MINIMUM FLASH
0 - 9.9 or 127 sec
1ST ALL RED AFTER FLASH
0 - 9.9 or 127 sec
RECALL MODES, BASE TIMINGS, PHASING & SEQUENCE, START-UP
NOTE: Blanks = 0, OFF, or controller default values
PHASES USED (MM-2-2-3-1)
PHASE
φ1 φ2 φ3 φ4 φ5 φ6 φ7 φ8
ON/OFF
SEQUENCE (MM-2-2-3-2)
1=Sequential, 2=Dual Ring, 3-7=Spec, 8 =Lead/Lag
LEAD/LAG MODES (MM-2-2-3-2-PGDN....only if Seq = Lead/lag)
PHASE
φ(1 & 2) φ(3 & 4) φ(5 & 6) φ(7 & 8)
CODE
Codes: 1 = No Reversal, 2 = Always Reverse, 3 = Rev. By CSO or Clock
LEAD/LAG BARRIERS
(MM-2-2-3-2- PGDN- PGDN...only if lead/lag)
LEAD/LAG BARRIERS ARE: ON/OFF
On = Barriers after each ring 1 and 2 phase pair in a vertical column
SPECIAL INCOMPATIBILITIES (MM-2-2-3-3)
PHASE
φ1 φ2 φ3 φ4 φ5 φ6 φ7 φ8
INCOMPAT PH 1-8
INCOMPAT PH 1-8