ipbxhookashmaximum Time in msec for maximum
hookash
900
ipbxhookashminimum Time in msec for minimum
hookash
100
ipbxhookashdelay Timeinmsectodelayhookash
action in case of hangup
200
ipbx answer hangup delay Time in msec for answer side
hangup delay
0
Other:
Parameter Description Default
ipbx concurrent line count Number of concurrent line per-
mitted
2
ipbx concurrent voip count Number of concurrent VoIP
segments permitted including
conferences
3
ipbx epoch clock limit Call progress, ringer and display
synchronization period in sam-
ples (16000 for two seconds and
48000 for six seconds)
16000
ipbx hook debounce Debounce test count for hook
on/off transitions
10
ipbxhookashenable A parameter added to disable
hookashprocessing
1
regionalization
TheRegionalizationsettingsareusedtoconguretheATAforlocaloperatingconventions.Theseinclude:
• CallProgressTones
• DefaultRingingPatterns
• DistinctiveRingingPatterns
• DistinctiveCallWaitingPatterns
• LEDPatternsandPriority
• VoiceandToneParameters
• SLACConguration
• CommandStrings
Call Progress Tones:
Callprogresstonesarespeciedbyalistofvaluesindicatingthenumberoftones,numberofon/off
transitions, frequency/signal level pairs and tone on/off times according to the following format:
no_of_tones, no_of_times, duration, {tone_element1_freq, tone_element1_db,
tone_element2_freq, tone_element2_db, …}, {tone_on_time1, tone_off_time1, tone_
on_time2, …}
•no_of_tones is the number of tone elements that are combined to form a tone. Each tone element