REGISTER # DESCRIPTION
40067
40087
40094
40160
40091 Scaled 0-1.000 is equal to 0-4000 counts.
EXAMPLE: Actual ModBus
® Return
2.000 8000 Counts
1.000 4000 Counts
0.100 400 Counts
40040-40041 Scaled 0-10 is equal to 0-4000 counts.
40045-40046
40050-40051 EXAMPLE: Actual ModBus
® Return
40055-40056 10 4000 Counts
40088-40090 7 2800 Counts
1 400 Counts
40086 Scaled 0-400 sec. is equal to 0-4000 counts.
EXAMPLE: Actual sec. ModBus
® Return
400 sec. 4000 Counts
100 sec. 1000 Counts
50 sec. 500 Counts
40060-40063 Scaled 0-20 mA is equal to 0-4000 counts.
EXAMPLE: Actual mA ModBus
® Return
20 mA 4000 Counts
12 mA 2400 Counts
1 mA 200 Counts
30008 The data from the TS310 as it will be read
40068-40085 needs to be converted. The conversion is
40129 done by taking the data and doing a Hex to
40156 decimal conversion.
EXAMPLE: Actual CH ModBus® Return
(Hex.) (Dec.)
1001 4097
0030 48
2332 9010