Technical data

Functions
7
DME
3
Functional description
The electronically controlled variable-speed motor of
the DME pump provides optimum control of the stroke
speed. As shown in the figure below, the duration of
each suction stroke is constant while the duration of
each discharge stroke varies according to the capacity
set, resulting in optimum discharge flow in any
operating situation.
The advantages:
The pump always operates at full stroke length,
irrespective of the capacity set; this ensures
optimum accuracy, priming and suction.
A capacity range of 1:800 for each pump size.
Smooth and constant dosing ensuring an optimum
mixing ratio at the injection point.
Significant reduction of pressure surges preventing
mechanical stress on diaphragm, hoses, pipes,
connections and other dosing parts exposed to
leakage and wear.
The installation is less affected by long suction and
discharge lines.
Easier dosing of highly viscous and gas-containing
liquids.
Fig. 3 Relation between stroke-frequency adjustment and capacity
TM01 8944 0900
Discharge
Suction
Suction
Discharge
Discharge
Suction
100 %
Capacity setting
Duration
Duration
Duration
50 %
10 %