Technical data
Functions
17
DME
3
Cable 1: Input for analog, pulse and leakage sensor
Cable 2: Output for alarm relay
Cable 3: Input for external stop, dosing monitor, output for dosing
★
Open collector can be used for a relay or a lamp.
Cable 4: Input for level sensor
★
The function for the potential-free contact set can be chosen from the display (NO = Normally Open and NC = Normally Closed).
Function
Pin holes
Plug type
1/brown 2/white 3/blue, 5 V 4/black 5/grey
Pulse X X contact
Pulse 5 V GND 5 VDC
Analog (-) mA input (+) mA input mA signal
Batch X X contact
Batch 5 V GND 5 VDC
Leakage X X contact
Leakage 5 V GND 5 VDC
Function
Pin holes
1/brown 2/white 3/blue
Alarm relay output NO X X
Alarm relay output NC X X
Function
Pin holes
Plug type
1/brown 2/white 3/blue, 5 V 4/black 5/grey
External stop input X X contact
External stop input 5 V GND 5 VDC
Dosing monitor input X X contact
Dosing monitor input GND 5 V 5 VDC
Dosing output (pump running)
open collector
★
X GND NPN
With internal 5 VDC power supply: max. 100 mA With external power supply: max. 24 VDC, 100 mA
TM03 7868 5006
TM03 7869 5006
Relay
Lamp
Power supply
Lamp
24 VDC
Function
Pin holes
Plug type
1/brown 2/white 3/blue, 5 V 4/black 5/grey
Low level
X
★
X
★
contact
Low level 5 V GND 5 VDC
Empty tank
X
★
X
★
contact
Empty tank 5 V GND 5 VDC