GRUNDFOS DATA BOOKLET DME Digital dosing pumps
DME Table of contents 2 1. 2. 3. General data 3 Performance range Digital Dosing 3 4 Identification 5 Type key 5 Functions 6 Overview of functions Functional description Control panel Menu Operating modes Dosing monitoring Control panel lock Units Wiring diagram DME-AR 6 7 8 10 11 14 15 15 16 4. Construction 18 5. Dimensions 19 6. Technical data 20 7. Pump selection 21 Standard range Non-standard range 21 23 8. Pumped liquids 24 9.
1 DME General data 1. General data Performance range p [bar] DME 18 16 14 12 10 8 DME 60-10 DME 375-10 6 4 DME 150-4 DME 940- 4 0 1 Fig.
1 DME Digital Dosing represents state-of-the-art technology. This patented Grundfos solution sets new standards, including new principles and methods. TM04 8479 0612 General data Digital Dosing Fig. 2 DME pumps Precise and easy setting The operator can easily install and set the pump to discharge exactly the quantity of dosing liquid required in the application.
2. Identification Type key Example: DME 60- 10 AR- PP/ E/ C- F- 3 1 A1 F Identification 2 DME Type range Maximum capacity [l/h] 60 150 375 940 Maximum pressure [bar] 4 10 Control variant AR AP B Standard Standard + Profibus Basic Dosing head material PP PV SS Polypropylene PVDF Stainless steel 1.4401 Gasket material E T V EPDM PTFE FKM Valve ball material C G SS T Ceramic Glass Stainless steel 1.
3 DME Overview of functions DME 60-940 AP TM04 8789 1313 DME 60-940 AR TM04 8827 1413 DME 60-940 B TM04 8826 1413 Functions 3.
3 DME Functions Functional description The electronically controlled variable-speed motor of the DME pump provides optimum control of the stroke speed. As shown in the figure below, the duration of each suction stroke is constant while the duration of each discharge stroke varies according to the capacity set, resulting in optimum discharge flow in any operating situation.
3 DME Functions Control panel Maximum capacity button ml/h 4 3 2 6 7 100% 1 Fig. 4 8 TM04 8481 0612 5 Control panel Pos. Description 1 Maximum capacity button (priming) 2 Navigation/settings 3 Menu/accept LCD display 5 Navigation/settings 6 Green indicator light 7 Red indicator light 8 On/Off button TM04 8702 5112 4 Front-fitted control panel Fig. 6 Side-fitted control panel TM04 8703 5112 Fig.
Indicator lights and alarm relay output Operating state Pump running Green indicator light Red indicator light Display On Off Normal indication Alarm relay output ★ 1 Functions 3 DME 1 2 3 NC NO C Set to stop Flashing Off Normal indication 1 2 3 NC NO C Pump fault Off On EEPROM 1 2 3 NC NO C Supply failure Off Off Off 1 2 3 NC NO C Pump running, low chemical level ★ 2 On On LOW 1 2 3 NC NO C Empty tank ★ 2 Off On EMPTY 1 2 3 NC NO C Analog signal < 2 mA Off On NO mA 1 2 3
3 DME Functions Menu The DME dosing pumps feature a user-friendly menu. To activate the menu, press the button . During initial start-up, all menu texts appear in the English language. You can set the menu to display other languages, see page 14. TM04 8484 0612 mA Fig.
3 DME Operating modes The pump ensures constant dosing according to the quantity set in l/h or ml/h by means of the and buttons. The pump automatically changes between the measuring units. Applies to DME-AR and DME-AP The pump ensures dosing according to an external analog signal. The dosed capacity is proportional to the input value in mA. Setting Input signal Dosed quantity as a percentage of the max.
3 DME Pulse-based batch control Applies to DME-AR and DME-AP The set quantity is dosed in batches at maximum capacity or the set capacity limitation. The time until the first dosing (NX) and the following sequences (IN) can be set in minutes, hours and days. The maximum time limit is 9 days, 23 hours and 59 minutes (9:23:59). The lowest acceptable value is one minute. IN must be higher than the time required to perform one batch. If IN is lower than the time required, the next batch will be ignored.
Maximum capacity limitation makes it possible to reduce the maximum capacity (MAX. CAP). It influences the functions in which the pump normally operates at maximum capacity. Under normal operating conditions, the pump cannot operate at a capacity higher than the one stated in the display. When pushing the maximum capacity button, the pump operates at 100 %. With the maximum capacity limitation function, a large pump can be set to operate as a much smaller pump.
3 DME Functions Languages Bus communication The display text can be displayed in one of the following languages chosen in the set-up menu: • English, German, French, Italian, Spanish, Portuguese, Dutch, Swedish, Finnish, Danish, Czech, Slovak, Polish, Russian. The DME-AP is available with a built-in module for bus communication with PROFIBUS DP systems. This module enables remote monitoring and setting via the fieldbus system. All DME features are available via bus communication.
3 Definitions Units Correct dosing stroke: A pulse from the dosing monitor corresponds to the internal stroke signal within acceptable time. Incorrect dosing stroke: There is no pulse from the dosing monitor corresponding to the internal stroke signal within the acceptable time (the pump is not pumping). It is possible to select metric units (litre/millilitre) and US units (gallons/millilitre).
3 DME Functions Wiring diagram DME-AR 2 3 5 1 4 2 3 5 1 4 2 3 1 4 2 3 2 5 4 1 Cable 1 Analog/pulse/leakage sensor Product No. 2 m cable: 96440447 5 m cable: 96440448 Fig. 16 Wiring diagram DME-AR 16 1 2 3 1 Cable 2 Relay Product No. 2 m cable: 96534214 5 m cable: 96534215 1 3 5 2 Cable 3 External stop Product No. 2 m cable: 96527109 5 m cable: 96527111 4 2 3 1 Cable 4 Level sensor Product No.
3 DME Pin holes Function 1/brown Pulse Pulse Analog Batch Batch Leakage Leakage 2/white 3/blue, 5 V X 5V X X 5V X 4/black GND (-) mA input Plug type 5/grey contact 5 VDC mA signal contact 5 VDC contact 5 VDC (+) mA input GND X 5V Functions Cable 1: Input for analog, pulse and leakage sensor X GND Cable 2: Output for alarm relay Pin holes Function Alarm relay output NO Alarm relay output NC 1/brown 2/white X X X 3/blue X Cable 3: Input for external stop, dosing monitor, output for
4 DME Construction 4. Construction 29 20 28 27 26 25 24 23 1 2 3 4 38 21 22 19 18 17 16 15 5 6 14 39 12 11 10 9 32 36 37 8 33 34 7 35 31 TM04 8488 0612 30 Fig. 17 Sectional drawing Material specification Pos. Description Material options O-ring EPDM/FKM/PTFE Material options Back plate PPE/PS 20 % glass fibre 23 2 Spring DIN 17223 TYPE C 24 Valve seat PP/PVDF/SS 1.4401/PTFE 3 Housing PPE/PS 20 % glass fibre 25 Valve ball 4 Hall sensor - Ceramic/Glass/SS 1.
5 DME A B Dimensions 5. Dimensions G TM02 7062 5106 D C F E 4xØ7 I H Fig. 18 Dimensions of DME 60 and 150 l/h A F G TM03 7884 5006 D C B E 4xØ7 I H Fig.
6 DME Technical data 6. Technical data DME Mechanical data Weight and size Maximum Maximum Maximum Maximum Maximum Maximum Maximum Maximum capacity capacity with anti-cavitation 75 % capacity with anti-cavitation 50 % (approx.) capacity with anti-cavitation 25 % (approx.) pressure stroke frequency suction lift during operation suction lift when priming with wet valves Signal input Signal output Sound pressure level 20 DME 150 DME 375 DME 940 60 45 33.4 16.1 10 150 112 83.5 40.
7 DME Pump selection 7. Pump selection Standard range Power supply: 1 x 100-240 V, 50/60 Hz switch-mode Mains plug: EU Valves: Single-ball on suction side; single-ball on discharge side Max. capacity [l/h] 60 60 150 150 376 376 940 Max. pressure [bar] 10 10 4 4 10 10 4 Control variant Materials Dosing Gaskets head Valve balls PP EPDM Ceramic 19/27 25/34 PP FKM Ceramic 19/27 25/34 PVDF FKM Ceramic 19/27 25/34 SS PTFE SS 1.
7 Pump selection 22 DME Max. capacity [l/h] 940 Max. pressure [bar] 4 Control variant B ★2 Materials Dosing Gaskets head Valve balls Connection ★ 1 PP EPDM Glass Rp 1 1/4 PP FKM Glass Rp 1 1/4 PVDF FKM Glass Rp 1 1/4 SS PTFE SS 1.
7 DME Maximum capacity - pressure [l/h]-[bar] Control variant Dosing head Gaskets Material Valve balls Control panel position Voltage Valve type Connection suction/discharge Mains plug DME 60-10 150-4 Control variant B AR AP 3: 1 x 100-240 V, 50/60 Hz 1: 2: Q: A1: A2: A3: A4: F: B: G: I: E: J: L: Standard Spring-loaded 19/27+ 25/34 mm Threaded, Rp 3/4 Threaded, Rp 1 1/4 Threaded, 3/4" NPT Threaded, 1 1/4" NPT EU USA, Canada UK Australia Switzerland Japan Argentina Head Gaskets PP E V
8 DME Pumped liquids 8. Pumped liquids The resistance table below is intended as a general guide for material resistance (at room temperature), and does not replace testing of the chemicals and pump materials under specific working conditions. The data shown are based on information from various sources available, but many factors (purity, temperature, abrasive particles, etc.) may affect the chemical resistance of a given material.
9. Further product information WebCAPS WebCAPS is a Web-based Computer Aided Product Selection program available on www.grundfos.com. WebCAPS contains detailed information on more than 220,000 Grundfos products in more than 30 languages. Information in WebCAPS is divided into six sections: • Catalogue • Literature • Service • Sizing • Replacement • CAD drawings.
9 DME Further product information Sizing 0 1 This section is based on different fields of application and installation examples and gives easy step-by-step instructions in how to size a product: • Select the most suitable and efficient pump for your installation. • Carry out advanced calculations based on energy, consumption, payback periods, load profiles, life cycle costs, etc. • Analyse your selected pump via the built-in life cycle cost tool.
9 DME Further product information GO CAPS Mobile solution for professionals on the GO! CAPS functionality on the mobile workplace. Subject to alterations.