Specifications
Fast loop response
Closed loop response
1.8 A inrush
1 A inrush
2 A inrush
Input Step
TPS1H100-Q1
SLVSCM2A –OCTOBER 2014–REVISED JANUARY 2014
www.ti.com
9.2.3 Application Curves
Figure 48 shows a test example of initial short circuit inrush current limit. Test condition: V
S
= 13.5 V, input is
from low to high, load is short to GND or with 470-µF capacitive load, external current limit is 2 A. CH1 is the
output current. CH3 is the input step.
Figure 49 shows a test example of a hard short-circuit inrush current limit. Test condition: V
S
= 13.5 V, input is
high, load is 5 µH + 100 mΩ, external current limit is 1 A. A short to GND suddenly happens.
Figure 49. Hard Short to GND Waveform
Figure 48. Initial Short to GND Waveform
36 Submit Documentation Feedback Copyright © 2014, Texas Instruments Incorporated
Product Folder Links: TPS1H100-Q1