Specifications
OUT
VS
Vol,off
FAULT
OPEN LOAD
VBAT
ST/CS
Rpd
ADC Full Scale
Range
Max Normal
Operating Current
On-state: Current limit, thermal fault
Off-state: Open load/ short to battery
Over
current
Normal
Open Load Current
On-state:
open load/short to battery
Current Sense
Voltage
Operating
Range
Vcs,H
TPS1H100-Q1
SLVSCM2A –OCTOBER 2014–REVISED JANUARY 2014
www.ti.com
Typical Application (continued)
Figure 46. Step 1: Distinguish Short to GND in On-State
Figure 47. Step 2: Distinguish Short to Battery in Off-State
9.2.2.2 AEC Q100-012 Test Grade A Certification
Short-circuit reliability is critical for smart high-side power switch devices. The standard of AEC-Q100-012 is to
determine the reliability of the devices when operating in a continuous short-circuit condition. Different grade
levels are specified according to the pass cycles. This device is qualified with the highest level, Grade A, 1
million times short to GND certification.
Three test modes are defined in the AEC Q100-012. See Table 3 for cold repetitive SCT – long pulse, cold
repetitive SCT – short pulse, and hot repetitive SCT.
34 Submit Documentation Feedback Copyright © 2014, Texas Instruments Incorporated
Product Folder Links: TPS1H100-Q1