Specifications

ZL112
Model
Nozzle diameter
Maximum suction flow rate
Air consumption
Maximum vacuum pressure
Maximum operating pressure
Supply pressure range
Standard supply pressure
Operating temperature range
ø1.2mm
100l/min (ANR)
63l/min (ANR)
84kPa
0.7MPa
0.2 to 0.5MPa
0.4MPa
5 to 50°C
Ejector Specifications
GZ30S
Part number
Fluid
Pressure range
Scale range (angular)
Accuracy
Class
Operating temperature range
Material
Air
100 to 100kPa
230°
± 3% F.S. (full span)
Class 3
0 to 50°C
Housing: Polycarbonate/ABS resin
Option Specifications
Vacuum pressure gauge specifications
Symbol
Standard
Part Number
Type of valve actuation
Fluid
Operating pressure range Internal pilot type
Ambient and fluid temperature
Response time (for 0.5MPa)
Note 1)
Maximum operating frequency
Manual operation
Pilot exhaust type
Lubrication
Mounting position
Impact/Vibration resistance
Note 2)
Enclosure
SYJ514-
N.C.
Air
0.2 to 0.5MPa
5 to 50°C
25ms or less
5Hz
Non-locking push type, Slotted locking type
Pilot valve individual exhaust type,
Main valve/Pilot valve common exhaust
Not required
Unrestricted
150/30m/s²
Dust proof
Standard
With valve
With vacuum pressure gauge
Adapter
Port exhaust
P
V
Supply/Release Valve Specifications
Note 1) Based on JIS B8374-1981 dynamic performance test. (coil temperature 20°C, at rated voltage, without surge
voltage suppressor)
Note 2) Impact resistance: No malfunction when tested with a drop tester in the axial direction and at a right angle to
the main valve and armature, one time each in both energized and deenergized states.
(initial value)
Vibration resistance: No malfunction when tested with one sweep of 8.3 to 2000Hz in the axial direction and at
a right angle to the main valve and armature, one time each in both energized and
deenergized states. (initial value)
Note 3) Refer to CAT.E143-B "SYJ300/500/700" for details on valves.
Series ZL