Technical data
Chapter 8 Analog input/output modules Manual VIPA System 200V
8-28 HB97E - SM - Rev. 09/19
... continue
Suppression of interference, limits of error input channels
Noise suppression for f=n x (f1 ±1%) (f1=interference frequency, n=1,2,...)
Common-mode interference
(U
CM
< 5V)
> 80dB
Series-mode noise (peak value of noise
< nominal value of input range
> 80dB
Crosstalk between the inputs > 50dB
Operational limit (only valid to 120W/s)
(in the entire temperature range, referring to input range)
Measuring range Tolerance
voltage input ±400mV, ±4V, ±10V ±0.3%
1 ... 5V ±0.7%
0 ... 10V ±0.4%
current input ±20mA ±0.3%
0 ... 20mA ±0.6%
4 ... 20mA ±0.8%
Resistors
0 … 600Ω, 0 …3kΩ
±0.4%
Resistance thermometer Pt100, Pt1000 ±0.4%
Ni100, Ni1000 ±1.0%
Basic error limit (only valid to 120W/s)
(during temperature is 25
°C, referring to input range)
Measuring range Tolerance
Voltage input 400mV, ±4V, ±10V ±0.2%
1 .. 5V ±0.5%
0 ... 10V ±0.3%
Current input ±20mA ±0.2%
0 ... 20mA ±0.4%
4 ... 20mA ±0.5%
Resistors
0 …600Ω, 0 … 3kΩ
±0.2%
Resistance thermometer Pt100, Pt1000 ±0.2%
Ni100, Ni1000 ±0.5%
Temperature error
(with reference to the input range)
measuring current
±0.005%/K
±0.015%/K
Linearity error
(with reference to the input range)
±0.02%
Repeatability (in steady state at 25°C
referred to the input range)
±0.05%
Suppression of interference, limits of error output channels
Crosstalk between the outputs > 40dB
Operational limit (in the entire temperature range, referring to output range)
Measuring range Tolerance
Voltage output ±10V ±0.4%
1)
0 … 10V ±0.6%
1)
1 … 5V ±0.8%
1)
Current output ±20mA ±0.3%
2)
0 … 20mA ±0.6%
2)
4 … 20mA ±0.8%
2)
continued ...