Technical data

Chapter 6 Analog input modules Manual VIPA System 200V
6-42 HB97E - SM - Rev. 09/19
Wiring diagram Schematic diagram
1
2
3
4
5
6
7
8
9
10
V
V
V
V
V
-Bus
Input
D
A
µP
Channel 0
+0
M0
Mux
Channel 1
+1
M0
.
.
.
82k
82k
1,6k
1,6k
Input data in Siemens S5 format is stored in a word. The word contains the
binary value and information bits:
Numeric notation:
Byte Bit 7 ... Bit 0
0 Bit 0: overflow bit
0: value within measuring range
1: measuring range exceeded
Bit 1: error bit (set at internal error)
Bit 2: activity bit (always 0)
Bit 7 ... 3: binary measured value (see table below)
1
Bit 6 ... 0: binary measured value (see table below)
Bit 7: sign
0 positive
1 negative
The following table shows the allocation of binary values to the respective
measured values.
Wiring and
schematic
diagram
Numeric notation