Specifications
MSD/PT0600/200 - Technical Reference Manual 59
Preset 5 Digital 5+6 is based on all the three
AES-3 inputs. In this set up phase meter and vec-
tor oscilloscope are assigned to bargraph channels
5, 6 (line #61 and #62), which are the physical
AES-3 input pair #3 (line #39 and #40).
Column A + B = Status Display Line Number + Destination ID
Column C = Status Display Source ID
Column D + E = Source Line Number + Source ID
Column F = Shows the physical input connection corresponding to the line number
in column D. This combination will always be the same.