Specifications
MSD/PT0600/200 - Technical Reference Manual 47
Preset 4 Digital+MS is based on the first AES-3
input pair #1. In this set up phase meter and vector
oscilloscope are assigned to bargraph channels 1,
2 (line #57 and #58), which are the physical AES-3
input signal (line #33 and #34). The bargraph chan-
nel 3,4 is used to monitor the SUM and DIF signal
of the MS measurement. .
Column A + B = Status Display Line Number + Destination ID
Column C = Status Display Source ID
Column D + E = Source Line Number + Source ID
Column F = Shows the physical input connection corresponding to the line number
in column D. This combination will always be the same.