Specifications
MSD/PT0600/200 - Technical Reference Manual 33
Preset 2 Digital is based on the digital AES-3
input. In this set up phase meter and vector oscillo-
scope are assigned to bargraph channels 1, 2 (line
#57 and #58), which are the physical AES-3 inputs
(line #35 and #36).
Column A + B = Status Display Line Number + Destination ID
Column C = Status Display Source ID
Column D + E = Source Line Number + Source ID
Column F = Shows the physical input connection corresponding to the line number
in column D. This combination will always be the same.