User`s manual

MSD100 Series - User’s Manual
Note: The last choice, REF, is for setting the
reference (test) level for that scale.
5 When the preferred scale is displayed, press
[SELECT]. The selected scale is displayed.
6 Press [EXIT] to return to the Main Menu.
4.8.2 SETTING THE PPM REFERENCE LEVEL
After you select the preferred PPM scale, you can set the
reference (test) level for that scale.
To set the PPM reference level:
1 Perform Steps 1 through 5 under Selecting Preferred
PPM scale.
2 After you press [SELECT], press the function keys for
and to set the reference level.
3 After you set the level, press [EXIT] to return to the
Main Menu.
4.8.3 USING THE LED OVERLOAD
INDICATORS
When an overload condition occurs, the following indica-
tors activate simultaneously:
• Two red LED overload indicators in the front plate
illuminate. The LED indicators, located directly above
the PPM bars, light up when the selected reference
level for the scale is reached (for example at +6dB for
Type I, Nordic scale).
• Split bars appear in the PPM bars in the LCD display.
4.8.4 USING THE PPM PEAK HOLD
FUNCTION
The Peak HOLD function enables you to check the maxi-
mum signal level reached during and after a recording
session. This helps you confirm that levels did not
exceed specified limits.
In the HOLD mode, the “flying” segments of the PPM
bars indicate the highest bar-graph values attained since
19