vomiting or food or drink if you ingest the battery or disassemble the battery. Seek
medical attention immediately.
Inhalation
Ingredients in the battery may cause respiratory allergies, and inhalation of vapor may
cause upper respiratory tract and lung allergies. Breathe fresh air and seek medical
attention immediately.
5 Fire Fighting Measures
Extinguishing media
Suitable fire extinguishing medium
Water or water mist, sand, fire blanket, dry powder or carbon dioxide
fire extinguisher
Inappropriate extinguishing
medium
None
Special hazards arising from this substance or mixture
1
In transportation and test engineering, risk factors such as electric box drop, extrusion, puncture, metal
short circuit, liquid immersion may occur, and electric shock and fire risk may occur;
2
If in a confined space, there may be a risk of gas explosion.
3
Liquids leaking from accidents, including improper handling of fire water, pose a risk of environmental
pollution.
Material prepare & training
Material prepare
1
Water mist fire extinguisher: use 1 9-liter water mist fire extinguisher or 2 6-liter water mist fire
extinguishers per 500KWH, which can extinguish ABCE fire (solid, non-flammable liquid, gas,
electrical fire under 36KV). Or carry electric or manual sprayers as water mist extinguishers. Suspension
type water - based fire extinguisher can be hung above the two cargoes.
2
Waterproof supplies: raincoat, rain boots, rubber gloves; Plastic wrap. Rags.
3
PPE: mask, high temperature gloves, safety glasses, half mask.
4
Smoke exhaust tools: every 20 meters 1 wall smoke exhaust fan, or mobile smoke exhaust fan. The
vehicle has ventilation holes.
5
Explosion-proof tools: keep open, such as open environment, vehicles/equipment not airtight. The test
must be closed equipment, such as high temperature furnace, high and low temperature impact test
instrument. Copper foil with a diameter of 200mm and a thickness of 8 microns shall be placed on the
equipment as pressure relief film. Room wall every 20 meters to have a fan, fan displacement at least
5,000 cubic meters per hour.