Power Connection
When connected to a standard Ethernet connection, NG Series Industrial Wireless Gateways require an
external power supply connection using the supplied A-coded M12 field wireable connector or optional
M12 power cable accessory.
! WARNING
HAZARDOUS ENVIRONMENT
RISK OF EXPLOSIVE ATMOSPHERE.
The power over ethernet function may not be utilized in a hazardous
atmosphere. Only a suitable DC power supply may be utilized to power the
equipment in a hazardous area.
The power connection also serves as an optional secondary power supply connection when using a PoE
plant network connection. If needed, use the supplied A-coded M12 field wirable connector or optional
M12 power cable accessory to connect to an external power supply to establish a redundant power supply
connection.
The secondary supply allows for continued operation should the primary supply fail. Switching between
the primary and secondary supply will cause the gateway to reboot and results in temporary loss of
wireless connectivity.
The A-coded M12 connection uses these wiring connections:
Table 2: M12 connector pin descriptions & wire colours
M12 Pin
Wire Colour
Description
1
Brown
IO – Reset 1
2
White
V+ (20-57 Vdc, 4W)
3
Blue
IO – Reset 2
4
Black
V-
The power cable and connector can be used as an alternative to the magnetic interface to reset the
gateway TCP/IP IPv4 address or restore the gateway to factory default settings.
Using an appropriate tool, the M12 power connector must be tightened to a torque of 0.6Nm.