13. Verify the status of device(s) you restarted.
a. In the Yokogawa “Field Wireless Management Console”, open Monitor”.
b. In the tool bar, click the Field Device Listbutton. The Field Device Listdialog box is
displayed.
c. For each type of device, verify that the status of each type of VP Series 2000 device is:
NR1210 Repeater
VP2010 Single Axis
VP2030 Tri-Axis
Configuration Status
Not Published
Published
Published
! NOTE
If the status is Session Timeout, you must resolve the timeout issue before proceeding.
14. To verify the device status:
a. In the Yokogawa “Field Wireless Management Console”, open Configurator”.
b. Select Sampling Data. The Sampling Datapane is displayed.
c. Click “Edit”. The “Sampling Settings” dialog box is displayed.
d. Verify that the firmware version, CF file version, and OID parameters are correct for the
device.
To provision devices on a Yokogawa network:
1. In the Yokogawa “Field Wireless Management Console, open Monitor”.
2. Choose Tools > OTA Provisioning Manager”.
3. To allow unprovisioned devices to join, select Enable Provisioning Network. Wait for
unprovisioned VP Series 2000 devices to display in the Provisioning Network list. Wait time may be 5
to 30 minutes and depends on the ISA network.
4. In the Target Devicetag field, select the device tag assigned to the device.
5. Select the devices desired and choose Start Provisioning”.
6. Wait for all devices to be provisioned and display in the Operating Network List”.