Owner`s manual

Dive Rite
Ch. 6 Pg. 14
Copyright, Dive Rite All Rights Reserved January 2009
Post-Dive Checklist
Name ____________________________________ Date __________ Time __________
Primary S/N ________ Secondary S/N ________
Sensor: S/N: (1) _________ (2) _________ (3) _________ (4) _________
Date Installed: (1) _________ (2) _________ (3) _________ (4) _________
Battery: Date Installed: Primary ___________ Secondary ___________
New Usage Total (Prev Total + #6, #7) Primary _____:_____ Secondary _____:_____
Initials NOTE: Initial upon completion of each task.
_____ 1. Rinse CCR with Fresh Water.
2
_____ 2. Record cylinder pressures. O :_________ Diluent:_________
_____ 3. Record Maximum Depth: _________ Record Dive time _____:_____
_____ 4. Record Rebreather Runtime: (dive+Pre/Post Dive) (hrs:min) _____:_____
2
_____ 5. Record accumulated service time on CO absorbent: (hrs:min) _____:_____
_____ 6. Record new usage on PRIMARY Battery: (dive+Pre/Post Dive) _____:_____
_____ 7. Record new usage on SECONDARY Battery: (dive+Pre/Post Dive) _____:_____
_____ 8. Update battery usage totals in header above.
_____ 9. Dry off handsets and check for auto shutdown.
2
_____ 10. Close O and diluent cylinder valves.
_____ 11. Will additional dives be made today??
_____ 12. If yes goto to step # 28
2
_____ 13. Bleed pressure from O and Diluent 1 regulators using manual addition valves.
st
_____ 14. Disconnect LP hoses from Head assembly, Manual Addition Valves, and ADV.
_____ 15. Remove Loop Hoses from ADV and T-Piece and Canister.
_____ 16. Remove ADV and T-Piece from Counter-Lungs.
_____ 17. Clean and Disinfect hoses, DSV, ADV, T-Piece and Counter-Lungs .
_____ 18. Hang Counter-Lungs and hoses to dry.
_____ 19. Disassemble canister, remove cartridge, Clean and Disinfect canister.
_____ 20. Wipe head assembly and store with sensors face down.
2
_____ 21. Record accumulated service time on CO absorbent: (hrs:min) _____:_____
_____ 22. If scrubber duration reached, dispose of cartridge responsibly.
_____ 23. If scrubber is to be re-used, wipe dry and store in air-tight container.
_____ 24. If NEXT dive is greater than 24 Hours remove and label batteries.
_____ 25. If batteries have not been removed, verify that both handsets have gone into
Sleep Mode, otherwise troubleshoot and correct.
2
_____ 26. Refill and replace O and Diluent Cylinders if necessary.
_____ 27. End of Checklist
2
_____ 28. Record accumulated service time on CO absorbent: (hrs:min) _____:_____
_____ 29. If scrubber duration reached, Replace Cartridge continue with Pre-Dive Checklist.
2
_____ 30. Refill and replace O and Diluent Cylinders if necessary.
_____ 31. Verify Handsets have gone into Sleep Mode, otherwise troubleshoot and correct.