Owner`s manual
Dive Rite
Ch. 6 Pg. 2
Copyright, Dive Rite All Rights Reserved January 2009
The hose for the bailout regulator should now be connected to the manifold. Loosen one of the
spare 3/8 port plugs using an 4mm Allen Key and install LP hose. If the wing is to be supplied by
the onboard diluent supply, remove the remaining 3/8 port plug and install the LP inflator hose
supplied with the wing.
The hoses and submersible pressure
gauges should now be routed through the
cutout in the mounting frame. The diluent
spg, manual diluent addition hose, bailout
regulator hose, LP inflator for wing (if
connected to onboard diluent regulator)
and LP ADV connection on the diver’s
left and the oxygen SPG and oxygen
manual addition hose on the diver’s right
(DO NOT pass the oxygen solenoid LP
hose). Since the cut-outs in the mounting
plate are just large enough for the spg to
pass through, the spgs must be passed
through the frame before the LP hoses.
Head Assembly
The head assembly houses the oxygen sensors, oxygen
premix tube and the solenoid. The oxygen cells and
harness are shipped in sealed bags. In order to install
the cells, the sensor plate must be removed. The plate
is secured in place with a single SS screw. Remove
the sensor plate and set aside. Inspect the solenoid
cable and insure that it is secure. Next, install the
Oxygen premix tube by inserting into the fitting on the solenoid. When
removal is needed, press on the locking ring and pull on the tube.
The next step is to remove the oxygen cells from the sealed
packaging. It is strongly suggested to inscribe the installation date and
the associated cell location. The numbering of the cells insures that
if during trouble shooting cell positions are swapped the cell can be
returned to its original location. Tracking the mV measurements over
time is useless unless the values always apply to the same cell.
Carefully screw each cell into the associated location (the positions
are marked on the sensor plate).
Cylinders with Hose Clamps
Cylinders with Cam Bands
and Cuttoff Valve on
Solenoid O2 Supply