Owner`s manual

2
O ptima FX Owner’s Manual
Ch. 3 Pg. 13
Copyright, Dive Rite All Rights Reserved January 2009
Stack Time Opt
NEXT SELECT
View Stack Time
NEXT SELECT
Max Stk Time 180
Used 53 Left 127
Set Stack Time
[_60] Minutes
Set Stack Time
NEXT SELECT
SECONDARY Handset Options and Programming
The secondary handset has many of the same options as the primary handset. The
notable differences are the lack of functions supporting the deco computer and set-point
control options. The secondary has FOUR additional options, “Stack Time Opt” ,
“Decompress Mode“, “Display Options” and “Set DIVA Mode”.
STACK TIME OPT
The stack timer is convenience reminder, and should not be counted
on as a life support feature. How useful this option is to the diver is
dependent on how faithfully the diver remembers to reset the counter after
each scrubber change. The stack timer cannot be disabled, but the user has the freedom to set their
own limits and can reset the timer at any time. Selecting “Stack Time Opt” under the “OPT” menu
allows the user to scroll through several options relating to the stack timer function.
VIEW STACK TIME
The “View Stack Time” option can be used at any time to view the
timer limits and how much UNDERWATER time has been put on the
scrubber. This is a VERY important concept to remember, time spent on
the loop but not at depth is NOT counted towards stack time. Scrubber
durations in excess of the limits (stack overrun) will be displayed as a
negative time remaining.
SET STACK TIME
The “Set Stack Time” option allows the user to set the scrubber
duration timer in 60 minute intervals ranging from 60 to 600 minutes.
Upon entering this function the stack time is set to 60 minutes, the diver
now must set the timer limit by using the left button to increment by 60
minutes at a time, with the right button programming the displayed time.
WARNING Even if the right button is not pressed, once the programming screen times out, the
scrubber limit will be set to whatever is currently displayed as the new limit. Time previously
counted ason the stack” is also reset. This function can be seen as setting the scrubber stack time
limit and resetting the counter to the new limit.