Technical data

FSG 2T PS
Portable VHF/AM Airband Transceiver
May 2010 DITTEL  D10077
23
4 Operation
4.1 Introduction
This section contains a description of the basic operation procedure
for the portable transceiver FSG 2T PS.
DANGER!
DO NOT OPERATE THIS RADIO IN AN EXPLOSIVE
ATMOSPHERE (PETROLEUM FUELS, SOLVENTS, DUST,
ETC.).
A front view of the FSG 2T PS is given on the last page of this manual.
Please fold out the back flap when reading the operation instructions.
4.2 Battery Check
If applicable, disconnect battery charger from External Supply
Socket
14
, before checking the battery supply.
Press the red test button of the battery indicator
11
.
The LED indicators
11
will light up.
5 LEDs ON = battery fully charged, supply OK!
3 to 4 LEDs ON = battery partially discharged; reduced
operation time when powered only from
the battery.
2 or less LEDs ON = battery discharged. The battery should
be recharged or the radio should be
powered by an external 12 Vdc source
of adequate capacity (e.g. automobile
battery).
Additionally the transceiver FSG 2T includes a 3 digit display of the
actual supply voltage level while in the DIRECT TUNE MODE. At dc
levels below 11 V the voltage digit value starts automatically flashing
for low supply warning!