Technical data
FSG 2T PS
Portable VHF/AM Airband Transceiver
May 2010 DITTEL D10077
21
3.4 Error Codes
Display in all Modes!
High Voltage: Continuously slightly too high supply voltage changes
value indication into HI (above 16.1 Vdc / below 16.5 Vdc).
Above approximately 16.5 Vdc, the radio automatically switches OFF
itself, at no display indication.
When supply is reduced to between 16 Vdc and 10.5 Vdc, the FSG 2T
comes back into operation.
Temperature Error: The whole LC display flashes. Temperature of
the Transmitter Power Amplifier is too high. The keyed transmitter will
be disabled.
Switch OFF the radio, wait a few seconds and switch ON again.
Process Error: The whole LC display flashes. A severe process error
must have occurred.
Try to revive the radio by switching OFF and ON again.
If the same error occurs contact a DITTEL approved repair facility!
Out-Of-Lock Error: The whole LC display flashes. A severe
frequency error must have occurred.
Try to revive the radio by switching OFF and ON again.
If the same error occurs contact a DITTEL approved repair facility!
2 Minutes TOT Time-Out-Timer: After two minutes continuous
transmitting the transmitter of the FSG 2T switches OFF itself and the
whole LC display flashes as long as the PTT key is pressed.
When the PTT key stuck accidentally it can be received with the
adjusted frequency although the display is flashing. After switching
the radio OFF and ON again it can be transmitted for another 2
minutes followed by receive mode.