Technical data
FSG 2T PS
Portable VHF/AM Airband Transceiver
May 2010 DITTEL D10077
13
2.5 Re-calibration Information
IMPORTANT!
For the first time after three years, FSG 2T equipment for
ground applications requires checking and re-calibration of
the high precision reference frequency (tolerance better than
±10 ppm).
For airborne applications, no frequency re-calibration is
necessary, since applications in the 25 kHz channel spacing
require a frequency accuracy tolerance of less than ± 20 ppm.
All tolerances include the full operating temperature range of
-20°C ... +55°C / -4°F ... +131°F.
Checking and re-calibration must be performed by the
equipment manufacturer or through authorized and approved
avionics services!
2.6 Operating License
IMPORTANT!
Depending on national regulations, VHF/AM ground and / or
VHF/AM airborne operation may require an individual national
operating license. Such license is usually granted by the
responsible National Telecommunications Authority, through
suitable application forms.
Aircraft registration, operator's name, address and operating
license payment details, radio type / model, Serial number,
ESTO number EASA.21O.1304, and DFS number D-0002/2002,
or, when applicable, the FCC ID number BVYFSG2T.
Example: