Datasheet
48 x 24 mm frontal
Fully programmable panel meter for AC/DC volts and amperes
measurement.
Configurable decimal point.
Controled by three keys situated on the bottom of the frontal display.
DESCRIPTION
INDICATOR for:
- AC/DC VOLTS (600V and 100V)
- AC/DC AMPERES (1A and 5A)
TECHNICAL SPECIFICATIONS
INPUT VOLTAGE CURRENT
AC Range 0÷600V 0÷100V 0÷1A 0÷5A
DC Range -199.9÷600V ±100V ±1A -1.999÷5A
Resolution 0.1V 0.1V 1mA 1mA
INPUT IMPEDANCE
Volts .............................................................................. 3M
Amperes ...................................................................... 14m
ACCURACY at 23ºC ±5ºC
DC; 600V AC, 5A AC ............................. ±(0.2% rdg + 3 digits)
100V AC, 1A AC .................................... ±(0.4% rdg + 4 digits)
Temperature coefficient ........................................ 100 ppm/ºC
Warm-up time ......................................................... 5 minutes
POWER SUPPLY AND FUSES (DIN 41661, not included)
PICA-E: 85-265V AC 50/60Hz and 100-300V DC F 0.1A/ 250V
PICA-E6: 21-53V AC 50/60Hz and 10.5-70V DC .. F 0.5A/ 250V
Power consumption ........................................................ 1.8W
CONVERSION
Technique ............................................................ Sigma-Delta
Resolution ................................................................. ±15 bits
Coversion rate ................................................................. 20/s
DISPLAY
Range .......................................... -1999÷9999 DC, 0÷9999 AC
Type ........................................................... 4 red digits 10mm
Diplay refresh rate ............................................................. 4/s
Display/input overrange indication ....................................
ENVIRONMENTAL CONDITIONS
Operating temperature ..................................... -10ºC ÷ +60ºC
Storage temperature ......................................... -25ºC ÷ +85ºC
Relative humidity (non condensing) .... ............... <95% @ 40ºC
Maximum altitude ......................................................... 2000m
Frontal protection degree ................................................. IP65
DIMENSIONS AND MOUNTING
Dimensions ................................................ 48 x 24 x 70 mm
Panel cutout ....................................................... 45 x 22 mm
Weight ........................................................................... 60g
Case material .............................. Polycarbonate s/ UL 94 V-0
Instruments include a sealing gasket and a fixing clip for
frontal and rear panel installation.
oue
PROGRAMMING
Display range: Inputs DC ................... -1999 ÷ 9999
Display range: Inputs DC .................. - 1999 ÷ 9999
Display range: Inputs AC ........................... 0 ÷ 9999
Display range: Inputs AC ........................... 0 ÷ 9999
Keys detail (bottom view)
Power supply Input
CONNECTIONS
ORDERING CODES
PICA-E: ......................85-265V AC 50/60Hz and 100-300V DC
PICA-E6: ...................... 21-53V AC 50/60Hz and 10.5-70V DC
PICA-E
1a
5a
600 100
600
5a
600
5a
100
1a
100
1a
CN1 POWER SUPPLY
PIN AC VERSION DC VERSION
1 AC LO -V DC
2 AC HI +V DC
CN2 SIGNAL INPUT
1 IN (COMMON)
2 100V / 600V (AC/DC)
3 1A / 5A (AC/DC)
Rear view
Cable insertion tool
31.07.12 30738202B