Operation Manual

- 37 -
0DT829 15/10/2012
47E
ADJUSTMENT LIMIT SWITCH
Adjusting the limit switch
1. Set the deceleration ramps to zero. (T5 - T6)
2. Calibrate the limit switch (C) on the gearmotor so the door stops approximately
200-300mm from the closure point.
3. Calibrate the opening limit switch (A) at the opening point.
4. Calibrate slowdown limit switch (B) in such a way that it engages at
approximately ¾ of the opening stroke.
5. Calibrate the opening speeds using trimmer (T3) and closure (T4).
6. Calibrate the opening (T5) and closure (T6) trimmers of the deceleration
ramps in such a way as to cause stopping in the actual door open and door
closed positions.
C
B
A
B
C
300
A
¾
ON
J1
1
L N
GND
CNT
T2
T4
T6
T1
T3
T5
DL1011 9 8 7 6 5 4 3 2 1
12
15
1617
13
14
41 40 20 9 8 4 3 2 1 1 0 LAMP1 11 12 13
+F -F U V W
ON
OFF
1 2 3 4
U24
J2
F2F1
230 V 50/60 Hz
FUSES
ID Value Dimension Circuit
F1 - F2 12A - 500V 10.3 x 38 monophase line
COMMAND TROUBLE VERIFY

curtain position
The curtain and the motors
don’t move
Control unit test was failed
(led 13 green OFF, led 14 red ON)
Opening Command The motor run with slog or
it doesn’t reach to the right
speed (the brake wasn’t
activated)
Check that jumper J2 has not been cut
During the closing
movement
The motors doesn’t made
deceleration ramp
Adjustment of the closing limit switch (C) at 300 mm from
the oor
Adjustment of the deceleration ramp by means the trimmer T6
NB for general diagnostics see also at page. 39
TROUBLESHOOTING
EN