INPUTS
Command Function Description
1 2 N.O Automatic closing Permanently closing the contact enables automatic closing.
1 3 N.O Opening The closure of the contact activates an opening operation.
1 4 N.O Closing The closing manoeuvre starts when the contact is closed.
41 40 N.C Reversal safety
device
Opening the safety contact triggers a reversal of the movement (reopening)
during a closing operation.
1 8 N.C Reversal safety
device
Opening the safety contact triggers a reversal of the movement (reopening)
during a closing operation.
1 9 N.C Stop Opening the safety contact stops the current operation.
1 9 N.O Non-pulse
command
Permanently opening the safety contact enables the operation by non-
pulse command
In this state, the opening (1-3/1-20) and closing (1-4) controls function only
if held in the pressed position, and the automation stops when the controls
are released.
All safety switches, the step-by-step control and the automatic closing
function are disabled.
1 20 N.O Partial opening The closing of the contact activates a partial opening operation of the
duration set with the RP trimmer.
1 11 N.C Closure limit switch The opening of the limit switch contact stops the closure operation.
1 12 N.C Limit switch
slowdown
The opening of the limit switch contact activates the slowdown in opening.
1 13 N.C Opening limit switch The opening of the limit switch contact stops the opening operation.
OUTPUTS
Output Value Description
1 +
0 -
24 V= / 0,5 A
Accessories power supply.
Power supply output for external accessories, including automation status
lamp.
LAMP 230 V~ / 50 W
Flashing light (LAMP).
Activated during opening and closing operations.
CNT
Counter activation
Activated in each closing motion
-F +F 24 V= / 0,5 A
Electric motor brake.
The output is active for the duration of both the opening and closing
operation.
230 V~ / 6 A 
U W V
M
3 ~